Search results for "Shoulder Prosthesis"
showing 5 items of 5 documents
A new method to evaluate the influence of the glenosphere positioning on stability and range of motion of a reverse shoulder prosthesis
2019
Abstract Purpose Shoulder instability and reduced range of motion are two common complications of a total reverse shoulder arthroplasty. In this work, a new approach is proposed to estimate how the glenoid component positioning can influence the stability and the range of motion of a reverse shoulder prosthesis. Materials and methods A standard reverse shoulder prosthesis has been analysed. To perform virtual simulation of the shoulder-prosthesis assembly, all the components of the prosthesis have been acquired via a 3D laser scanner and the solid models of the shoulder bones have been reconstructed through CT images. Loads on the shoulder joint have been estimated using anatomical models d…
Optimal positioning of the humeral component in the reverse shoulder prosthesis.
2014
Total reverse shoulder arthroplasty is becoming more and more the standard therapeutic practice for glenohumeral arthropathy with massive lesions of the rotator cuff. The biomechanical principle of this prosthesis is represented by the reversion of the normal anatomy of the shoulder joint. This non-anatomical prosthesis leads to a medialization of the rotation centre of the glenohumeral joint and also to a distalization of the humeral head. All that causes a deltoid tension increasing so allowing a larger abduction of the arm. Main complications of the reverse shoulder prosthesis are due to the joint instability, the scapular notching and the wear of the polyethylene insert. The main goal o…
Numerical study of the components positioning influence on the stability of a reverse shoulder prosthesis
2014
Aim of this paper is to setup a novel procedure able to analyze performances of a reverse shoulder prosthesis when different geometrical configurations are assumed. Nowadays, such a prosthesis is widely used but, because of its novelty, data in literature give poor information about performances and limits to its applicability. The activity has been divided into the following steps. At the beginning the shape of the prosthesis has been digitally acquired via a 3D scanner. Then, CAD models of all prosthetic components have been geometrically optimized in a way to obtain final entities suitable for numerical simulations. After that, CAD assemblies have been created between prosthetic componen…
Influence of the metaphysis positioning in a new reverse shoulder prosthesis
2016
Aim of this work is to investigate the behaviour of a new reverse shoulder prosthesis, characterized by a humeral metaphysis with a variable offset, designed to increase the range of movements and to reduce the impingement. In particular, by means of virtual prototypes of the prosthesis, different offset values of the humeral metaphysis have been analysed in order to find the best positioning able to maximize the range of movements of the shoulder joint. The abduction force of the deltoid, at different offset values, has been also estimated. The study has been organized as follows. In the first step, the point clouds of the surfaces of the different components of the prosthesis have been ac…
Dispositif virtuel d'aide à la chirurgie de l'épaule
2008
The goal of this research is to design a virtual reality prototype to assit an orthopedic surgeon during the replacement of the glenohumeral joint by prosthesis. This system aims to optimize the movements of prosthesized shoulder joint from a choice of various scenarios of pose. These works encompasses several topics such as : orthopedic surgery, image analysis, computer graphics and virtual reality. The chosen process includes a phase of modelling of the bony part of the articulation by simple geometric forms, this model is parameterized from radios or CT scans ; a phase of simulation of the movements of healthy glenohumeral joint ; nally the phase of simulation of cutting and drilling wit…